Fault Code Finder
Heater flashing E 517 H at 11pm? Fridge showing Error 3? Type in the code and we'll tell you what it means, what you can safely check yourself, and when it's time to call someone.
Truma Combi heaters (gas, E and D)
24 codesVoltage too high
The heater is seeing more than about 16.4 volts on its 12-volt supply, which is too high, so it stops to protect its electronics.
Battery too low – heater has stopped
The battery voltage has fallen below 10 volts, so the heater has shut down.
Flame not detected – usually no gas reaching the heater
The heater tried to light but couldn't see a flame.
Gas valve closed or flame unstable
Another gas-supply fault.
Flue or air intake blocked (older gas heaters)
On older gas Combis, Truma lists this with E 212 H: the combustion air intake or the exhaust outlet is blocked.
Gas not getting through – flame failure
The heater couldn't establish or keep a flame.
Gas valve closed or flame unstable
Truma groups this with E 121 H.
Flue or air intake blocked (or no gas)
On older heaters this means the combustion air intake or the exhaust outlet (the flue on the outside of the van) is blocked.
Gas supply interrupted while running
Very similar to E 517 H: the gas supply dropped out, this time while the heater was already running, so it switched off.
Gas supply interrupted – heater has locked out
The heater tried to light or keep burning on gas but the gas didn't arrive properly, so it shut itself down to stay safe.
Too many resets – heater blocked for 15 minutes
You (or the system) have reset a fault more than four times within 15 minutes, so the heater locks itself out for a while.
Room temperature sensor fault
The heater can't get a sensible reading from its room temperature sensor, so it doesn't know how warm the van is.
Electric overheat protection tripped
The safety cut-out on the Combi E's electric (230-volt) heating has tripped because something overheated.
Hot water mode with an empty water heater
The heater has been asked to heat water but the water heater inside it is empty, so it's getting too hot.
Warm air can't get out – heater overheating
Hot air isn't escaping properly, or the heater can't draw air in, so it's getting too hot.
Battery getting low – heater may stop soon
Your leisure battery has dropped below about 10.4 volts.
Window open above the flue
Some vans have a switch on the window above the heater's outside flue.
No mains (230-volt) power to the heater
Only on Combi E models with electric heating.
Heater has no 12-volt power or has lost contact with the panel
The control panel can't talk to the heater.
Hot water mode with an empty water heater (newer heaters)
The newer-generation version of W 17 H: you've asked for hot water but the water heater is empty.
Air overheating (newer heaters)
The newer-generation version of W 18 H: the heater is overheating because air isn't flowing freely through the vents and ducts.
Gas dropped out in mixed (gas plus electric) mode
You're running in mixed mode and the gas supply was interrupted, so the heater is carrying on with electricity only.
Diesel heater out of fuel
The heater isn't getting enough diesel.
Diesel heater lost contact with the panel
On diesel Combi D heaters this means there's no connection between the heater and the control panel – similar to W 255 H on gas models.
Truma VarioHeat
3 codesNo flame – fuel or air problem
The VarioHeat isn't detecting a flame because it's not getting enough gas or enough air.
Air vents or intake blocked
The VarioHeat's warm-air outlet or the intake for the air it circulates is blocked, so it can't move heat around properly.
Battery voltage low
On the VarioHeat this warns that the battery has dropped below about 10.4 volts.
Alde Compact wet heating boilers
8 codesPanel can't talk to the boiler
There's a fault in the connection between the boiler and the control panel.
Combustion fan fault
The fan that feeds air to the gas burner isn't reaching the right speed, so the boiler can't burn gas safely.
Boiler couldn't light the gas
The boiler tried to ignite the gas (liquefied petroleum gas, or LPG) and couldn't.
Battery too low – boiler stopped
The battery voltage has fallen below about 10.8 volts (10.5 volts on the 3010), so the boiler stops.
Boiler electronics overheated
The boiler's circuit board, or the cupboard it's in, has got too hot.
Heating fluid overheated
The antifreeze-and-water mix (glycol) circulating through your radiators got too hot.
Overheat protection tripped (red sensor)
On the 3010 and 3020, one of the boiler's overheat cut-outs (the one on the red cable) has tripped.
Window open near the flue
A switch on the window near the boiler's wall flue has detected it's open, so gas heating pauses.
Webasto Air Top diesel heaters
12 codesControl unit error
The heater's brain (the control unit, sometimes called the ECU or electronic control unit) has spotted a problem with itself or its settings.
No start — heater didn't ignite
The heater tried to start twice and couldn't get a flame going, so it has given up.
Flame went out — repeatedly
The heater did light, but the flame went out more than three times, so it shut itself down.
Voltage too low or too high
The supply voltage reaching the heater went outside its safe range, so it switched off.
Flame detected too early
The heater 'saw' a flame before it should have, which shouldn't happen, so it stopped for safety.
Temperature sensor fault
The heater has lost its signal from a temperature sensor (the wire is broken or shorted).
Fuel pump circuit fault
There's a break or short circuit in the wiring to the little fuel metering pump (the one that ticks while the heater runs), or the pump itself has failed.
Fan motor fault
The heater's internal fan motor is open circuit, short-circuited, overloaded or blocked.
Glow pin fault
The glow pin (the part that heats up to light the fuel) has an open or short circuit.
Overheating
The heater got too hot, so it cut the fuel and shut down.
Overheating sensor fault
The sensor that watches for overheating has a broken or shorted connection, so the heater can't protect itself and won't run.
Heater locked out
After serious faults such as repeated no-starts or overheating, the heater has locked itself out to stop unburnt fuel building up and to protect itself.
Eberspächer Airtronic diesel heaters
13 codesOver-voltage cut-off
The supply voltage went too high, above about 16V on a 12V system, so the heater switched off to protect itself.
Under-voltage cut-off
The voltage dropped too low for too long (around 20 seconds), so the heater shut down.
Overheating
The overheating sensor detected the heater getting too hot.
Operating lockout after overheating
The heater has seriously overheated (code 017, a hardware temperature limit was exceeded) and has now locked itself out.
Glow plug open circuit
The control box can't see the glow plug, the part that heats up to light the fuel.
Glow plug short circuit or overload
The glow plug circuit is drawing too much current or is shorted to earth, so the heater stopped.
Blower motor open circuit
The control box can't detect the blower (fan) motor.
Fuel pump open circuit
There's a break in the circuit to the fuel metering pump, the ticking pump usually mounted under the van.
Locked out — too many failed starts
The heater has failed to start too many times and has locked itself out.
No start — safety time exceeded
The heater tried to light but didn't detect a flame within the allowed time, so it stopped.
Flame went out while running
The heater was running but the flame went out.
External temperature sensor open circuit
If you have a separate room temperature sensor fitted, the heater has lost its signal from it.
Flame sensor open circuit
The control box has lost its signal from the flame sensor, which tells it whether the burner is alight.
Budget 'Chinese' diesel heaters (LCD controller)
9 codesVoltage too low
On most budget diesel heaters with an LCD (liquid crystal display) controller, E-01 means the supply voltage is too low.
Voltage too high
Commonly means the supply voltage is above the permitted level.
Glow plug fault
Usually means a problem with the glow plug or its circuit, so the heater can't light the fuel.
Fuel pump fault
Generally means a problem with the fuel pump or its wiring.
Overheating
On most of these controllers E-05 means the heater has overheated, usually from blocked airflow.
Fan motor fault
Commonly means a problem with the fan motor or its circuit.
Controller communication fault
Usually means the controller and the heater have stopped talking to each other, often because of a loose plug in the controller cable.
Flame out / failed to start
Generally means the flame went out or never took hold, often from low fuel or air in the fuel line.
Ignition failure after repeated attempts
Typically means the heater has failed to start several times in a row, usually because of another underlying problem such as fuel, voltage or the glow plug.
12V compressor fridges (Secop / Danfoss BD35F & BD50F)
6 codesBattery protection cut-out
The compressor's control unit has switched off because the battery voltage is outside its protection setting.
Too many starts or fan over-current
Either the compressor or fan has tried to start too many times in a short period, or the cooling fan is drawing too much current (over 0.5 amps on average).
Compressor motor start error
The compressor couldn't start: the motor (rotor) is blocked, or the pressure difference in the cooling system is too high, over 5 bar.
Minimum motor speed error
The cooling system is working so hard that the compressor can't hold its minimum speed (about 1,850 rpm, revolutions per minute).
Electronic unit overheated
The compressor's electronic control unit has got too hot, either because the fridge has been working too hard or because it's very hot around it, so it has shut down to protect itself.
Thermostat sensor fault
The temperature sensor the electronic unit uses (an NTC thermistor, a temperature-sensitive resistor) is shorted or disconnected, so the unit can't control the temperature.
Dometic absorption (3-way) fridges
13 codesNo cooling in gas / mains / 12V mode
The fridge has run on gas (E07), mains (E08) or 12V (E09) but isn't producing any cooling.
Low battery in stand-alone gas mode
In stand-alone gas mode, the fridge uses its own small batteries to keep the gas control running, and they're getting low.
Gas lockout after 3 ignition attempts
The fridge tried three times to light on gas and failed, so it has locked out gas mode.
No 12V or voltage under 10.5V
The fridge wants 12V but either isn't getting it or it's below 10.5V.
No mains or voltage under 195V
On AES models, the fridge is trying to run on mains but there's no 230V supply, or it's below 195V.
Gas ignition failed
The red failure light and the gas indicator flash (with a beep on AES models) because the burner didn't light.
Temperature sensor (NTC) fault
The fridge's temperature sensor, an NTC (negative temperature coefficient) thermistor, has a bad contact or has failed.
Gas mode blocked for 15 minutes
Gas operation has been blocked for 15 minutes.
Temperature sensor fault
The temperature sensor in the fridge compartment is faulty.
No mains power or mains too low
The fridge is set to mains but there's no 230V supply, or it's below 190V.
No 12V power
The fridge is set to 12V but isn't getting a 12V supply.
Door open more than 2 minutes
The door has been open (or not properly shut) for over two minutes.
12V overvoltage (over 16V)
The fridge is seeing more than 16V on its 12V supply, which is too high.
Thetford N3000 / N4000 fridges
10 codesSeveral errors at once
When every light on the panel blinks, the fridge has logged more than one fault at the same time.
Gas lockout: flame didn't light within 30 seconds
The fridge tried to light its gas burner but didn't detect a flame within 30 seconds, so it locked out gas mode.
12V heater not working
The 12V heating element isn't on when it should be.
12V supply out of range
The 12V supply to the fridge is too low or too high.
D+ (engine running) signal missing
The fridge is set to 12V but isn't getting the 'D+' signal that tells it the engine is running.
230V heater fault
The 230V heating element is drawing much less current than it should, which Thetford says indicates a defective 230V element.
230V supply out of range
The mains supply is outside the range the fridge accepts (190–260V).
No energy source available
In automatic mode, the fridge can't find any usable power: no mains, no 12V with the engine running, and no gas.
Display and power board lost communication
The control panel and the fridge's main power board at the back have stopped talking to each other.
Temperature sensor fault: running in backup mode
The fridge's temperature sensor (thermistor) has failed or come loose.
Victron SmartSolar / BlueSolar MPPT controllers
13 codesBattery temperature too high
The controller has spotted that your leisure battery is too hot, so it has stopped charging to protect it.
Battery voltage too high
The battery voltage has gone higher than the controller considers safe, so it has stopped charging.
Controller overheated despite reduced output current
The controller has got too hot even after cutting back how much it charges.
Controller over-current
Too much current flowed through the controller for a moment, so it protected itself.
Maximum bulk time exceeded
The controller has been in its main 'bulk' charging stage longer than its time limit allows.
Current sensor issue
The controller's own current measurement has gone out of range.
Terminal overheated
The big power terminals on the controller are getting too hot.
Power stage issue
Part of the controller's internal power electronics has a problem.
PV over-voltage
The voltage coming from your solar panels (PV, short for photovoltaic) is higher than the controller can safely handle.
PV over-current
The current from the solar panels has gone over the controller's rated limit.
PV input shutdown
The controller has deliberately shorted its solar input internally to stop the battery being overcharged.
BMS connection lost
The controller is set to take orders from a BMS (battery management system, the 'brain' in many lithium batteries), but it isn't hearing from it.
Settings data lost
The controller has lost its saved settings.
Victron Orion-Tr Smart B2B chargers
3 codesBattery voltage too high
The leisure battery voltage is higher than the B2B (battery-to-battery) charger expects, so it has paused.
Terminal overheated
The charger's power terminals are overheating, usually because of a loose bolt or unsuitable cable.
Charger short circuit
Too much current flowed on the battery side, often when something with a big surge (like an inverter) is connected.
Thetford cassette toilets
5 codesThree-level fill indicator
Some models have three lights.
Electric flush not working
Pressing the flush does nothing.
Level indicator not working
The fill lights never come on.
Cassette missing or not seated properly
A flashing red light means the toilet can't detect the waste cassette: it's either not there or not pushed fully home.
Cassette nearly full
The red light means the waste cassette only has room for about 2 more litres, which is two or three more uses.
Dometic cassette toilets
4 codesCassette three-quarters full
An early warning that the cassette is three-quarters full.
Cassette full
The waste cassette is full and needs emptying.
Cassette not detected
The toilet can't detect the cassette, and it won't flush without one.
Flush water low
The flush water needs topping up.
Every code is checked against the manufacturer's own manuals or troubleshooting guides. Each page links to its source. Last reviewed October 2026.