What it means
Too much current flowed through the controller for a moment, so it protected itself. It resets itself.
What you can check yourself
- Check whether a big load switched on or off suddenly, such as an inverter, a kettle on the inverter or a compressor fridge.
- Avoid running large inverter loads directly when the battery is low. Victron suggests charging the battery to a higher voltage helps.
- Improve cooling around the controller.
- See whether it happens again under normal use.
Likely causes
- Sudden switching of large loads
- Rapid changes in sunshine (clouds passing)
- An overloaded inverter on the same battery
When to call a pro
If it happens regularly, get an auto electrician to review how your inverter and loads are wired relative to the controller.
Good to know about Victron SmartSolar / BlueSolar MPPT controllers
- Codes show in the VictronConnect app and on the controller's display if it has one.
- Many errors clear themselves once the condition goes away. A firmware update fixes a surprising number.
Understand the part
Other Victron codes
Err 1Battery temperature too highErr 2Battery voltage too highErr 17Controller overheated despite reduced output currentErr 20Maximum bulk time exceededErr 21Current sensor issueErr 26Terminal overheatedErr 28Power stage issueErr 33PV over-voltageErr 34PV over-currentErr 38 / Err 39PV input shutdownErr 67BMS connection lostErr 119Settings data lost
Checked against: Victron Energy documentation. Last reviewed October 2026. General guidance only, not a diagnosis.