What it means
The battery voltage has fallen below about 10.8 volts (10.5 volts on the 3010), so the boiler stops. It restarts on its own once the voltage gets back to 11 volts.
What you can check yourself
- Charge the leisure battery from hook-up, solar or the engine.
- Switch off other big power users.
- Check the battery terminals are tight.
- Wait – the boiler resets automatically once the voltage recovers.
Likely causes
- Flat leisure battery
- Worn-out battery
- Charging fault or poor connections
When to call a pro
If the battery is healthy but the message keeps appearing, ask a habitation engineer or auto electrician to check the 12-volt system.
Good to know about Alde Compact wet heating boilers
- Alde panels show text messages rather than numbered codes.
- Most faults reset by switching the boiler's 12V supply off and back on, usually at the habitation master switch. Never open the boiler to do it.
Understand the part
Other Alde codes
Connection failurePanel can't talk to the boilerFan failureCombustion fan faultGas failureBoiler couldn't light the gasOverheat PCBBoiler electronics overheatedOverheat glycolHeating fluid overheatedOverheat red failOverheat protection tripped (red sensor)Window openWindow open near the flue
Checked against: Alde operating instructions. Last reviewed October 2026. General guidance only, not a diagnosis.