What it means
The supply voltage went too high, above about 16V on a 12V system, so the heater switched off to protect itself.
What you can check yourself
- Note whether it happens with the engine running, on solar or on hook-up. That points to which charger is pushing the voltage up.
- If you have a voltmeter, check battery voltage while charging.
- Switch off, let the voltage settle and try again.
Likely causes
- Faulty alternator or regulator
- Faulty or misconfigured battery charger, solar controller or DC-DC charger
When to call a pro
Get an auto electrician to check your charging system, because sustained over-voltage can damage other kit too.
Good to know about Eberspächer Airtronic diesel heaters
- These three-digit codes appear on EasyStart timers and diagnostic tools. The newer EasyStart Pro shows plain-text messages instead (for example 'Overheat. Heater locked.').
- Too many failed starts locks the heater out (050). It needs the fault memory cleared with a compatible controller or by a dealer.
Understand the part
Other Eberspächer codes
011Under-voltage cut-off012Overheating015Operating lockout after overheating020Glow plug open circuit021Glow plug short circuit or overload031Blower motor open circuit048Fuel pump open circuit050Locked out — too many failed starts052No start — safety time exceeded053 (also 054, 055, 056)Flame went out while running060External temperature sensor open circuit064Flame sensor open circuit
Checked against: Eberspächer troubleshooting manual (via UK distributor). Last reviewed October 2026. General guidance only, not a diagnosis.