What it means
The controller has lost its saved settings. This one doesn't clear itself.
What you can check yourself
- In VictronConnect, restore factory defaults.
- Disconnect all power from the controller for 3 minutes.
- Reconnect and power up.
- Re-enter your settings, especially battery voltage and battery type.
Likely causes
- Corrupted settings memory
- An interrupted update or power glitch
When to call a pro
If it happens again, report it to your Victron dealer.
Good to know about Victron SmartSolar / BlueSolar MPPT controllers
- Codes show in the VictronConnect app and on the controller's display if it has one.
- Many errors clear themselves once the condition goes away. A firmware update fixes a surprising number.
Understand the part
Other Victron codes
Err 1Battery temperature too highErr 2Battery voltage too highErr 17Controller overheated despite reduced output currentErr 18Controller over-currentErr 20Maximum bulk time exceededErr 21Current sensor issueErr 26Terminal overheatedErr 28Power stage issueErr 33PV over-voltageErr 34PV over-currentErr 38 / Err 39PV input shutdownErr 67BMS connection lost