What it means
The compressor couldn't start: the motor (rotor) is blocked, or the pressure difference in the cooling system is too high, over 5 bar.
What you can check yourself
- Switch off and leave it for several minutes so the pressures can even out, then switch on again.
- Check the battery voltage and connections, because a weak supply makes starting harder.
- Make sure the fridge's ventilation isn't blocked.
Likely causes
- Restarting too soon after switching off (pressures not yet equalised)
- Poor ventilation around the condenser
- Low voltage at start-up
- Mechanically stuck compressor
When to call a pro
If it still won't start after a proper rest with good voltage, call a refrigeration engineer.
Good to know about 12V compressor fridges (Secop / Danfoss BD35F & BD50F)
- Most 12V compressor fridges in campervans (many Dometic, Vitrifrigo and Isotherm models) use a Secop BD35F or BD50F compressor. If a diagnostic LED is fitted, it flashes these codes. The sequence repeats every four seconds.
- Fridges with their own digital display may show the manufacturer's own codes instead.
Understand the part
Other Secop (formerly Danfoss) codes
1 flashBattery protection cut-out2 flashesToo many starts or fan over-current4 flashesMinimum motor speed error5 flashesElectronic unit overheated6 flashesThermostat sensor fault
Checked against: Secop electronic unit instructions. Last reviewed October 2026. General guidance only, not a diagnosis.