If you can smell gas: turn the gas off at the cylinder, open doors and windows, don't use switches or naked flames, and get out. If there's any risk of fire or someone feels unwell, call 999. Never try to adjust a gas burner yourself.
What it means
The red failure light and the gas indicator flash (with a beep on AES models) because the burner didn't light.
What you can check yourself
- If you smell gas, turn off at the cylinder, ventilate and get out.
- Check the gas cylinder and gas valves are open.
- Once gas is sorted, press the reset button as described in the manual.
- Use 230V or 12V meanwhile. Never touch the burner.
Likely causes
- Empty or closed gas supply
- Air in the line
- Faulty burner or ignition
When to call a pro
If it keeps failing with gas available, get a Gas Safe registered engineer or habitation engineer.
Good to know about Dometic absorption (3-way) fridges
- Newer RMD 10.5 fridges show W (warning) and E (error) codes. Older RM 8 fridges with AES or MES control flash a red failure light alongside the mode that has a problem.
- Absorption fridges need to be roughly level to cool properly. If it's not cooling, check that first.
Understand the part
Other Dometic codes
E07 / E08 / E09No cooling in gas / mains / 12V modeE14Low battery in stand-alone gas modeE50Gas lockout after 3 ignition attemptsFailure LED + 12 flashingNo 12V or voltage under 10.5VFailure LED + 230 flashingNo mains or voltage under 195VFailure LED + temperature LEDs flashingTemperature sensor (NTC) faultTank StopGas mode blocked for 15 minutesW01Temperature sensor faultW05No mains power or mains too lowW06No 12V powerW10Door open more than 2 minutesW1112V overvoltage (over 16V)
Checked against: Manufacturer's manual (ManualsLib copy). Last reviewed October 2026. General guidance only, not a diagnosis.