What it means
There's a break or short circuit in the wiring to the little fuel metering pump (the one that ticks while the heater runs), or the pump itself has failed.
What you can check yourself
- With the heater off, find the fuel pump (usually under the van near the tank) and check its plug is connected and not corroded.
- Look along the pump wiring for chafing or damage, especially where it runs near the chassis or exhaust.
- Switch off and try one restart after checking.
Likely causes
- Corroded or disconnected pump plug
- Damaged wiring to the pump
- Failed metering pump
When to call a pro
If the wiring looks fine, have a specialist test the pump and replace it if needed.
Good to know about Webasto Air Top diesel heaters
- The same F codes are used on the Air Top 2000 STC and the Air Top Evo 40 / 55.
- No display? The heater flashes the code instead: five quick flashes, then a number of slow flashes. Count the slow ones: that's the F number.
- Repeated failed starts or overheating will lock the heater out (F12). F13 is a permanent lockout that needs a Webasto dealer.
- MultiControl controllers show their own H codes, which aren't covered here.
Understand the part
Other Webasto codes
F00Control unit errorF01No start — heater didn't igniteF02Flame went out — repeatedlyF03Voltage too low or too highF04Flame detected too earlyF06Temperature sensor faultF08Fan motor faultF09Glow pin faultF10OverheatingF11Overheating sensor faultF12Heater locked out