Stop using it until it's sorted. Restarting over and over can make things worse — and with heaters, a blocked flue or exhaust leak can let carbon monoxide into the van. Make sure your CO alarm works.
What it means
On older heaters this means the combustion air intake or the exhaust outlet (the flue on the outside of the van) is blocked. Truma also lists a closed gas valve, a faulty regulator, overheating or failed electronics. A blocked flue is a safety issue, so take it seriously.
What you can check yourself
- Don't keep resetting it – switch the heater off.
- Go outside and look at the heater's flue cowl: clear snow, ice, leaves or anything stuck in it, and make sure the van isn't parked hard against a wall or hedge.
- Check the cylinder and gas taps are open.
- Let the heater cool, then acknowledge the code and try once more.
- Make sure your carbon monoxide alarm is working.
Likely causes
- Snow, ice, leaves or debris in the flue cowl
- Van parked against an obstruction
- Gas valve closed
- Faulty gas pressure regulator or electronics
When to call a pro
If the flue is clear and the code returns, stop using the heater and get a Truma service agent or Gas Safe engineer to check the flue and the gas system.
Good to know about Truma Combi heaters (gas, E and D)
- W means a warning: the heater carries on as best it can and the warning clears itself once things are back in range. E means a fault: the heater stops. The H on the end just means 'heater'.
- On a CP plus panel, turn the knob to the warning triangle and press it to read the code. Fix the cause, then press the knob again to clear it.
- Reset more than four times in 15 minutes and the heater blocks itself for 15 minutes (E 607 H). Stop, find the cause, then try once.
- There are two generations of codes. Older Combis show two- or three-digit codes (E 112 H, W 24 H); newer ones show 400-600 series codes (E 517 H, W 401 H). Some numbers are described slightly differently between the two, so treat the meaning as a strong pointer rather than gospel.
Understand the part
Other Truma codes
E 43 HVoltage too highE 44 HBattery too low – heater has stoppedE 112 HFlame not detected – usually no gas reaching the heaterE 121 HGas valve closed or flame unstableE 122 HFlue or air intake blocked (older gas heaters)E 202 HGas not getting through – flame failureE 211 HGas valve closed or flame unstableE 507 HGas supply interrupted while runningE 517 HGas supply interrupted – heater has locked outE 607 HToo many resets – heater blocked for 15 minutesE 621 HRoom temperature sensor faultE 632 HElectric overheat protection trippedW 17 HHot water mode with an empty water heaterW 18 HWarm air can't get out – heater overheatingW 24 HBattery getting low – heater may stop soonW 42 HWindow open above the flueW 45 HNo mains (230-volt) power to the heaterW 255 HHeater has no 12-volt power or has lost contact with the panelW 401 HHot water mode with an empty water heater (newer heaters)W 402 HAir overheating (newer heaters)W 408 HGas dropped out in mixed (gas plus electric) modeE 122 HDiesel heater out of fuelE 131 HDiesel heater lost contact with the panel
Checked against: Truma technical guidance. Last reviewed October 2026. General guidance only, not a diagnosis.