What it means
The leisure battery voltage is higher than the B2B (battery-to-battery) charger expects, so it has paused. It resets once the voltage drops.
What you can check yourself
- Check what else is charging the leisure battery (solar, mains hook-up charger).
- Check the Orion's battery settings in VictronConnect match your battery type.
- Wait for the voltage to drop and check it resets.
Likely causes
- Other charging equipment connected to the battery
- A charger fault
- Wrong charge voltage settings
When to call a pro
If it persists with other chargers off, get an auto electrician to check the charging system.
Good to know about Victron Orion-Tr Smart B2B chargers
- Codes show in the VictronConnect app.
Understand the part
Other Victron codes
Checked against: Victron Energy documentation. Last reviewed October 2026. General guidance only, not a diagnosis.