What it means
The fridge's temperature sensor, an NTC (negative temperature coefficient) thermistor, has a bad contact or has failed.
What you can check yourself
- Check food temperatures with a thermometer.
- Switch off and on again.
- Check the sensor clip on the fins inside the fridge hasn't come loose.
Likely causes
- Loose sensor contact
- Faulty sensor
When to call a pro
Dometic says to contact authorised Dometic service, which can be a habitation engineer.
Good to know about Dometic absorption (3-way) fridges
- Newer RMD 10.5 fridges show W (warning) and E (error) codes. Older RM 8 fridges with AES or MES control flash a red failure light alongside the mode that has a problem.
- Absorption fridges need to be roughly level to cool properly. If it's not cooling, check that first.
Understand the part
Other Dometic codes
E07 / E08 / E09No cooling in gas / mains / 12V modeE14Low battery in stand-alone gas modeE50Gas lockout after 3 ignition attemptsFailure LED + 12 flashingNo 12V or voltage under 10.5VFailure LED + 230 flashingNo mains or voltage under 195VFailure LED + GAS flashingGas ignition failedTank StopGas mode blocked for 15 minutesW01Temperature sensor faultW05No mains power or mains too lowW06No 12V powerW10Door open more than 2 minutesW1112V overvoltage (over 16V)
Checked against: Copy of the manufacturer's manual. Last reviewed October 2026. General guidance only, not a diagnosis.