If you can smell gas: turn the gas off at the cylinder, open doors and windows, don't use switches or naked flames, and get out. If there's any risk of fire or someone feels unwell, call 999. Never try to adjust a gas burner yourself.
What it means
The VarioHeat isn't detecting a flame because it's not getting enough gas or enough air. Truma treats E 16 H the same way. VarioHeat is designed for propane only.
What you can check yourself
- Any smell of gas: turn the cylinder off, ventilate, get out and call a Gas Safe engineer.
- Check the cylinder has gas and the valve and the heater's gas tap are open.
- Use propane – Truma says VarioHeat is for propane only.
- Check the outside air intake and exhaust for snow, ice, leaves or debris.
- Acknowledge the code and try again.
Likely causes
- Empty or closed gas cylinder
- Butane instead of propane
- Blocked air intake or exhaust
- Low gas pressure
When to call a pro
If the gas and the outside vents are fine and the code returns, call a Truma service agent or Gas Safe engineer.
Good to know about Truma VarioHeat
- VarioHeat is designed to run on propane only.
- Some VarioHeat code numbers mean something different on a Combi, so make sure you're looking at the right heater.
Understand the part
Other Truma codes
Checked against: Truma technical guidance — codes for this product vary between models, so check your own manual too. Last reviewed October 2026. General guidance only, not a diagnosis.