What it means
On the 3010 and 3020, one of the boiler's overheat cut-outs (the one on the red cable) has tripped. Alde points to air in the system or low fluid as the usual reasons.
What you can check yourself
- Switch off and let the boiler cool.
- Check the expansion tank: when cold, the fluid should be at least 1 cm above minimum.
- Bleed air from the heating system as your handbook shows.
- Reset by turning the 12-volt supply to the boiler off and on.
Likely causes
- Air in the heating system
- Low fluid level
- Circulation pump problem
When to call a pro
If it trips again after bleeding and topping up, contact your dealer or an Alde service partner.
Good to know about Alde Compact wet heating boilers
- Alde panels show text messages rather than numbered codes.
- Most faults reset by switching the boiler's 12V supply off and back on, usually at the habitation master switch. Never open the boiler to do it.