What it means
The heater's internal fan motor is open circuit, short-circuited, overloaded or blocked. Without the fan the heater can't run safely, so it stops.
What you can check yourself
- Switch off and let it cool.
- Check the warm-air inlet and outlet grilles and ducting for blockages: clothes, bags or debris pulled against the intake.
- Check the heater's wiring plugs are secure.
- Try one restart.
Likely causes
- Blocked air inlet or outlet
- Fan seized or obstructed
- Wiring fault to the motor
- Worn drive motor
When to call a pro
If the fan still won't run, a Webasto agent will need to inspect or replace the motor unit.
Good to know about Webasto Air Top diesel heaters
- The same F codes are used on the Air Top 2000 STC and the Air Top Evo 40 / 55.
- No display? The heater flashes the code instead: five quick flashes, then a number of slow flashes. Count the slow ones: that's the F number.
- Repeated failed starts or overheating will lock the heater out (F12). F13 is a permanent lockout that needs a Webasto dealer.
- MultiControl controllers show their own H codes, which aren't covered here.
Understand the part
Other Webasto codes
F00Control unit errorF01No start — heater didn't igniteF02Flame went out — repeatedlyF03Voltage too low or too highF04Flame detected too earlyF06Temperature sensor faultF07Fuel pump circuit faultF09Glow pin faultF10OverheatingF11Overheating sensor faultF12Heater locked out