What it means
Only on Combi E models with electric heating. You've asked the heater to use mains electricity but it isn't getting any, or its electric overheat protection has tripped.
What you can check yourself
- Check you're plugged into hook-up and the site bollard's trip switch hasn't gone.
- Check the van's mains consumer unit and reset any tripped circuit.
- If you need heat now, switch the heater to gas mode.
- Your Combi handbook explains resetting the 230-volt overheat protection – only do this if it doesn't involve removing any covers.
Likely causes
- Not plugged in, or the site supply tripped
- Tripped circuit breaker in the van
- Electric overheat protection tripped
- Blown internal mains fuse
When to call a pro
If the mains supply is fine and the code persists, a qualified electrician or Truma service agent must check the heater's mains fuse – never open the heater yourself.
Good to know about Truma Combi heaters (gas, E and D)
- W means a warning: the heater carries on as best it can and the warning clears itself once things are back in range. E means a fault: the heater stops. The H on the end just means 'heater'.
- On a CP plus panel, turn the knob to the warning triangle and press it to read the code. Fix the cause, then press the knob again to clear it.
- Reset more than four times in 15 minutes and the heater blocks itself for 15 minutes (E 607 H). Stop, find the cause, then try once.
- There are two generations of codes. Older Combis show two- or three-digit codes (E 112 H, W 24 H); newer ones show 400-600 series codes (E 517 H, W 401 H). Some numbers are described slightly differently between the two, so treat the meaning as a strong pointer rather than gospel.
Understand the part
Other Truma codes
E 43 HVoltage too highE 44 HBattery too low – heater has stoppedE 112 HFlame not detected – usually no gas reaching the heaterE 121 HGas valve closed or flame unstableE 122 HFlue or air intake blocked (older gas heaters)E 202 HGas not getting through – flame failureE 211 HGas valve closed or flame unstableE 212 HFlue or air intake blocked (or no gas)E 507 HGas supply interrupted while runningE 517 HGas supply interrupted – heater has locked outE 607 HToo many resets – heater blocked for 15 minutesE 621 HRoom temperature sensor faultE 632 HElectric overheat protection trippedW 17 HHot water mode with an empty water heaterW 18 HWarm air can't get out – heater overheatingW 24 HBattery getting low – heater may stop soonW 42 HWindow open above the flueW 255 HHeater has no 12-volt power or has lost contact with the panelW 401 HHot water mode with an empty water heater (newer heaters)W 402 HAir overheating (newer heaters)W 408 HGas dropped out in mixed (gas plus electric) modeE 122 HDiesel heater out of fuelE 131 HDiesel heater lost contact with the panel
Checked against: Copy of the manufacturer's manual. Last reviewed October 2026. General guidance only, not a diagnosis.