Stop using it until it's sorted. Restarting over and over can make things worse — and with heaters, a blocked flue or exhaust leak can let carbon monoxide into the van. Make sure your CO alarm works.
What it means
The voltage coming from your solar panels (PV, short for photovoltaic) is higher than the controller can safely handle. It resets once the panel voltage drops, but the panel layout needs checking.
What you can check yourself
- Note when it happens. Cold, bright mornings push panel voltage highest.
- Check the controller's maximum PV voltage, which is the first number in its name (for example 100 on a 100/30).
- Add up the open-circuit voltage (Voc) of the panels wired in series and compare it with that limit.
- If you've recently added panels in series, that's the likely culprit.
Likely causes
- Too many panels wired in series for the controller
- Cold weather raising panel voltage
- A controller too small for the array
When to call a pro
Get an auto electrician or solar installer to rewire the panels (for example series to parallel) or fit a bigger controller, because sustained overvoltage can destroy the unit.
Good to know about Victron SmartSolar / BlueSolar MPPT controllers
- Codes show in the VictronConnect app and on the controller's display if it has one.
- Many errors clear themselves once the condition goes away. A firmware update fixes a surprising number.
Understand the part
Other Victron codes
Err 1Battery temperature too highErr 2Battery voltage too highErr 17Controller overheated despite reduced output currentErr 18Controller over-currentErr 20Maximum bulk time exceededErr 21Current sensor issueErr 26Terminal overheatedErr 28Power stage issueErr 34PV over-currentErr 38 / Err 39PV input shutdownErr 67BMS connection lostErr 119Settings data lost
Checked against: Victron Energy documentation. Last reviewed October 2026. General guidance only, not a diagnosis.