If you can smell gas: turn the gas off at the cylinder, open doors and windows, don't use switches or naked flames, and get out. If there's any risk of fire or someone feels unwell, call 999. Never try to adjust a gas burner yourself.
What it means
The fridge tried to light its gas burner but didn't detect a flame within 30 seconds, so it locked out gas mode.
What you can check yourself
- If you smell gas, turn off the gas at the cylinder, open doors and windows, don't use switches or flames, and get out.
- Check the gas cylinder isn't empty and its valve is open.
- Check the fridge's gas isolation tap in the van is open.
- Switch the fridge off and on again to retry. Air in the pipe after a cylinder change can take a couple of tries.
- Run the fridge on 230V or 12V meanwhile. Don't touch or poke at the burner.
Likely causes
- Empty cylinder or closed valve
- Air in the gas line after a cylinder change
- Ignition (spark) or electrode problem
- Dirty burner or jet, or wrong gas pressure
When to call a pro
If it still won't light with gas definitely available, book a Gas Safe registered engineer or habitation engineer. Never adjust the burner yourself.
Good to know about Thetford N3000 / N4000 fridges
- N3000 and N4000 fridges share the same error numbers. Older N3000 panels show the code as a pattern of lights rather than a number.
- On the N4000, hold all three buttons together until the flashing stops to see the code.
Understand the part
Other Thetford codes
All lights blinkingSeveral errors at onceError 412V heater not workingError 612V supply out of rangeError 7D+ (engine running) signal missingError 8230V heater faultError 10230V supply out of rangeError 11No energy source availableError 12Display and power board lost communicationError 13Temperature sensor fault: running in backup mode
Checked against: Thetford manual. Last reviewed October 2026. General guidance only, not a diagnosis.