What it means
The controller is set to take orders from a BMS (battery management system, the 'brain' in many lithium batteries), but it isn't hearing from it.
What you can check yourself
- Check the cable or link between the BMS and the controller is connected and undamaged.
- Check the BMS or lithium battery itself is switched on.
- If you no longer use a BMS, change the controller's 'BMS' setting from Y to N where available, or reset it to factory defaults in VictronConnect.
Likely causes
- BMS cable unplugged or damaged
- BMS switched off
- A controller still set for a BMS that has been removed
When to call a pro
If you have a lithium system and can't restore the link, get the auto electrician who installed it to check it, because the BMS link protects the battery.
Good to know about Victron SmartSolar / BlueSolar MPPT controllers
- Codes show in the VictronConnect app and on the controller's display if it has one.
- Many errors clear themselves once the condition goes away. A firmware update fixes a surprising number.
Understand the part
Other Victron codes
Err 1Battery temperature too highErr 2Battery voltage too highErr 17Controller overheated despite reduced output currentErr 18Controller over-currentErr 20Maximum bulk time exceededErr 21Current sensor issueErr 26Terminal overheatedErr 28Power stage issueErr 33PV over-voltageErr 34PV over-currentErr 38 / Err 39PV input shutdownErr 119Settings data lost
Checked against: Victron Energy documentation. Last reviewed October 2026. General guidance only, not a diagnosis.