If you can smell gas: turn the gas off at the cylinder, open doors and windows, don't use switches or naked flames, and get out. If there's any risk of fire or someone feels unwell, call 999. Never try to adjust a gas burner yourself.
What it means
The boiler tried to ignite the gas (liquefied petroleum gas, or LPG) and couldn't. Usually the cylinder is empty or a tap is closed, but it can also be wrong gas pressure or an ignition fault.
What you can check yourself
- Any smell of gas: turn the cylinder off, ventilate, get out and call a Gas Safe engineer.
- Check the cylinder has gas and the main gas tap and the boiler's tap are open.
- Light a hob burner first – Alde suggests this to check gas is reaching the van.
- Switch the boiler off, wait about 10 seconds and switch it back on.
- If it still shows, reset by turning the boiler's 12-volt supply off and on (usually via the habitation master switch).
Likely causes
- Empty gas cylinder
- Main gas tap or boiler tap closed
- Incorrect gas pressure or an iced regulator
- Faulty ignition
When to call a pro
If gas is clearly available and the boiler still won't light, book an Alde service partner or Gas Safe engineer.
Good to know about Alde Compact wet heating boilers
- Alde panels show text messages rather than numbered codes.
- Most faults reset by switching the boiler's 12V supply off and back on, usually at the habitation master switch. Never open the boiler to do it.
Understand the part
Other Alde codes
Connection failurePanel can't talk to the boilerFan failureCombustion fan faultLow battery voltageBattery too low – boiler stoppedOverheat PCBBoiler electronics overheatedOverheat glycolHeating fluid overheatedOverheat red failOverheat protection tripped (red sensor)Window openWindow open near the flue
Checked against: Alde operating instructions. Last reviewed October 2026. General guidance only, not a diagnosis.