Stop using it until it's sorted. Restarting over and over can make things worse — and with heaters, a blocked flue or exhaust leak can let carbon monoxide into the van. Make sure your CO alarm works.
What it means
The heater has seriously overheated (code 017, a hardware temperature limit was exceeded) and has now locked itself out. This is a safety lock, not something to keep resetting.
What you can check yourself
- Switch the heater off and leave it off.
- Check for obvious blocked ducting or intakes so you can tell the engineer.
- Don't try to bypass or repeatedly restart it.
Likely causes
- Severe overheating from blocked airflow
- Control box fault (Eberspächer's listed remedy is to replace the control box)
When to call a pro
Call an Eberspächer specialist, because the official fix for 015/017 is control box replacement.
Good to know about Eberspächer Airtronic diesel heaters
- These three-digit codes appear on EasyStart timers and diagnostic tools. The newer EasyStart Pro shows plain-text messages instead (for example 'Overheat. Heater locked.').
- Too many failed starts locks the heater out (050). It needs the fault memory cleared with a compatible controller or by a dealer.
Understand the part
Other Eberspächer codes
010Over-voltage cut-off011Under-voltage cut-off012Overheating020Glow plug open circuit021Glow plug short circuit or overload031Blower motor open circuit048Fuel pump open circuit050Locked out — too many failed starts052No start — safety time exceeded053 (also 054, 055, 056)Flame went out while running060External temperature sensor open circuit064Flame sensor open circuit
Checked against: Eberspächer troubleshooting manual (via UK distributor). Last reviewed October 2026. General guidance only, not a diagnosis.