Stop using it until it's sorted. Restarting over and over can make things worse — and with heaters, a blocked flue or exhaust leak can let carbon monoxide into the van. Make sure your CO alarm works.
What it means
The heater got too hot, so it cut the fuel and shut down. This is almost always restricted airflow. If it happens repeatedly the heater can lock itself out permanently (shown as F13), which needs a dealer to clear.
What you can check yourself
- Stop using the heater and let it cool down completely.
- Check the warm-air outlet and the return-air inlet aren't blocked by bags, bedding or clothes.
- Check the ducting isn't squashed, kinked or disconnected.
- Make sure the outlet vents in the van are open.
- Only restart once you've found and cleared the cause.
Likely causes
- Blocked air inlet or outlet
- Crushed or kinked ducting
- Closed outlet vents
- Damaged heater casing or seal
When to call a pro
If F10 keeps coming back with clear ducting, or the heater shows F13 (permanent lockout), call a Webasto service agent.
Good to know about Webasto Air Top diesel heaters
- The same F codes are used on the Air Top 2000 STC and the Air Top Evo 40 / 55.
- No display? The heater flashes the code instead: five quick flashes, then a number of slow flashes. Count the slow ones: that's the F number.
- Repeated failed starts or overheating will lock the heater out (F12). F13 is a permanent lockout that needs a Webasto dealer.
- MultiControl controllers show their own H codes, which aren't covered here.
Understand the part
Other Webasto codes
F00Control unit errorF01No start — heater didn't igniteF02Flame went out — repeatedlyF03Voltage too low or too highF04Flame detected too earlyF06Temperature sensor faultF07Fuel pump circuit faultF08Fan motor faultF09Glow pin faultF11Overheating sensor faultF12Heater locked out
Checked against: Manufacturer's manual (ManualsLib copy). Last reviewed October 2026. General guidance only, not a diagnosis.