Stop using it until it's sorted. Restarting over and over can make things worse — and with heaters, a blocked flue or exhaust leak can let carbon monoxide into the van. Make sure your CO alarm works.
What it means
The big power terminals on the controller are getting too hot. That usually means a loose or poor connection, which can be a fire risk.
What you can check yourself
- Cover the panels or isolate the solar input, then isolate the battery before touching any wiring.
- Check the terminal screws or bolts are properly tight.
- Check the cable is the right size, and that fine-stranded cable has proper ferrules or crimped ends.
- Look for discoloured, melted or scorched insulation. If you find any, don't reconnect.
- Reconnect and monitor. The error resets itself once the terminals cool.
Likely causes
- Loose terminal screws
- Undersized cable
- Fine-stranded cable without ferrules
- Damaged or corroded terminals
When to call a pro
If you see any heat damage or aren't confident with the wiring, get an auto electrician to sort it before using the solar again.
Good to know about Victron SmartSolar / BlueSolar MPPT controllers
- Codes show in the VictronConnect app and on the controller's display if it has one.
- Many errors clear themselves once the condition goes away. A firmware update fixes a surprising number.
Understand the part
Other Victron codes
Err 1Battery temperature too highErr 2Battery voltage too highErr 17Controller overheated despite reduced output currentErr 18Controller over-currentErr 20Maximum bulk time exceededErr 21Current sensor issueErr 28Power stage issueErr 33PV over-voltageErr 34PV over-currentErr 38 / Err 39PV input shutdownErr 67BMS connection lostErr 119Settings data lost
Checked against: Victron Energy documentation. Last reviewed October 2026. General guidance only, not a diagnosis.