What it means
The antifreeze-and-water mix (glycol) circulating through your radiators got too hot. Usually that's because there's air trapped in the system or the circulation pump isn't moving the fluid.
What you can check yourself
- Switch the boiler off and let it cool.
- Check the expansion tank level – Alde's older manuals say at least 1 cm above the minimum mark when cold – and top up with the recommended Alde fluid if it's low.
- Bleed the air out of the system as your handbook describes.
- Check the circulation pump is switched on.
- Once the fluid is below 50°C, reset by turning the boiler's 12-volt supply off and back on.
Likely causes
- Air pockets in the heating system
- Low fluid in the expansion tank
- Circulation pump not running or faulty
- Running at high power with poor circulation
When to call a pro
If it overheats again after bleeding and topping up, get an Alde service partner to check the pump and the system.
Good to know about Alde Compact wet heating boilers
- Alde panels show text messages rather than numbered codes.
- Most faults reset by switching the boiler's 12V supply off and back on, usually at the habitation master switch. Never open the boiler to do it.
Understand the part
Other Alde codes
Connection failurePanel can't talk to the boilerFan failureCombustion fan faultGas failureBoiler couldn't light the gasLow battery voltageBattery too low – boiler stoppedOverheat PCBBoiler electronics overheatedOverheat red failOverheat protection tripped (red sensor)Window openWindow open near the flue