If you can smell gas: turn the gas off at the cylinder, open doors and windows, don't use switches or naked flames, and get out. If there's any risk of fire or someone feels unwell, call 999. Never try to adjust a gas burner yourself.
What it means
The fridge tried three times to light on gas and failed, so it has locked out gas mode.
What you can check yourself
- If you smell gas, turn off at the cylinder, ventilate and get out.
- Check the cylinder isn't empty and all gas valves are open. Dometic's first remedy is to replace the cylinder.
- Reset the error (power button 2 seconds on TFT, MODE button 2 seconds on LED) and let it retry.
- After a cylinder change, Dometic suggests cycling it off and on 3–4 times to clear air from the line.
- Don't touch the burner.
Likely causes
- Empty cylinder
- Closed gas valve
- Air in the line
- An ignition or burner fault
When to call a pro
If gas is definitely available and it still locks out, call a Gas Safe registered engineer or habitation engineer.
Good to know about Dometic absorption (3-way) fridges
- Newer RMD 10.5 fridges show W (warning) and E (error) codes. Older RM 8 fridges with AES or MES control flash a red failure light alongside the mode that has a problem.
- Absorption fridges need to be roughly level to cool properly. If it's not cooling, check that first.
Understand the part
Other Dometic codes
E07 / E08 / E09No cooling in gas / mains / 12V modeE14Low battery in stand-alone gas modeFailure LED + 12 flashingNo 12V or voltage under 10.5VFailure LED + 230 flashingNo mains or voltage under 195VFailure LED + GAS flashingGas ignition failedFailure LED + temperature LEDs flashingTemperature sensor (NTC) faultTank StopGas mode blocked for 15 minutesW01Temperature sensor faultW05No mains power or mains too lowW06No 12V powerW10Door open more than 2 minutesW1112V overvoltage (over 16V)
Checked against: Dometic manual. Last reviewed October 2026. General guidance only, not a diagnosis.