What it means
The glow plug circuit is drawing too much current or is shorted to earth, so the heater stopped.
What you can check yourself
- Switch off.
- Look for any visibly damaged or chafed wiring at the heater.
- Try one restart. If 021 returns, stop and book it in.
Likely causes
- Shorted glow plug
- Damaged wiring harness shorting to earth
When to call a pro
Get a heater specialist to test the glow plug and harness.
Good to know about Eberspächer Airtronic diesel heaters
- These three-digit codes appear on EasyStart timers and diagnostic tools. The newer EasyStart Pro shows plain-text messages instead (for example 'Overheat. Heater locked.').
- Too many failed starts locks the heater out (050). It needs the fault memory cleared with a compatible controller or by a dealer.
Understand the part
Other Eberspächer codes
010Over-voltage cut-off011Under-voltage cut-off012Overheating015Operating lockout after overheating020Glow plug open circuit031Blower motor open circuit048Fuel pump open circuit050Locked out — too many failed starts052No start — safety time exceeded053 (also 054, 055, 056)Flame went out while running060External temperature sensor open circuit064Flame sensor open circuit
Checked against: Eberspächer troubleshooting manual (via UK distributor). Last reviewed October 2026. General guidance only, not a diagnosis.