What it means
The voltage dropped too low for too long (around 20 seconds), so the heater shut down. It's very common on a cold night with a tired leisure battery, because glow plug start-up draws a lot of current.
What you can check yourself
- Charge the leisure battery or start the engine, then try again.
- Check the heater fuse and fuse holder.
- Clean and tighten the battery terminals and the heater's earth (negative) connection.
- Look for corrosion on connectors.
Likely causes
- Flat or ageing battery
- Corroded battery terminals or earth
- Undersized or long supply cables
- Poor fuse or fuse holder contact
When to call a pro
If the battery tests fine and 011 persists, get an auto electrician to check for voltage drop in the supply wiring.
Good to know about Eberspächer Airtronic diesel heaters
- These three-digit codes appear on EasyStart timers and diagnostic tools. The newer EasyStart Pro shows plain-text messages instead (for example 'Overheat. Heater locked.').
- Too many failed starts locks the heater out (050). It needs the fault memory cleared with a compatible controller or by a dealer.
Understand the part
Other Eberspächer codes
010Over-voltage cut-off012Overheating015Operating lockout after overheating020Glow plug open circuit021Glow plug short circuit or overload031Blower motor open circuit048Fuel pump open circuit050Locked out — too many failed starts052No start — safety time exceeded053 (also 054, 055, 056)Flame went out while running060External temperature sensor open circuit064Flame sensor open circuit
Checked against: Eberspächer troubleshooting manual (via UK distributor). Last reviewed October 2026. General guidance only, not a diagnosis.