What it means
The compressor's control unit has switched off because the battery voltage is outside its protection setting. It's protecting your battery. On the standard 12V setting it cuts out at about 10.4V and comes back at about 11.7V, though fridge makers can set it differently.
What you can check yourself
- Charge your leisure battery or plug into hook-up.
- Check the fridge fuse and the battery terminals.
- Check the fridge cable isn't too thin or too long. Voltage drop at start-up is a common trigger even with a decent battery.
Likely causes
- Low leisure battery
- Undersized or long fridge cables causing voltage drop
- Loose or corroded connections
When to call a pro
If it trips with a healthy battery, get an auto electrician to check cable size and voltage drop at the compressor.
Good to know about 12V compressor fridges (Secop / Danfoss BD35F & BD50F)
- Most 12V compressor fridges in campervans (many Dometic, Vitrifrigo and Isotherm models) use a Secop BD35F or BD50F compressor. If a diagnostic LED is fitted, it flashes these codes. The sequence repeats every four seconds.
- Fridges with their own digital display may show the manufacturer's own codes instead.
Understand the part
Other Secop (formerly Danfoss) codes
2 flashesToo many starts or fan over-current3 flashesCompressor motor start error4 flashesMinimum motor speed error5 flashesElectronic unit overheated6 flashesThermostat sensor fault
Checked against: Secop electronic unit instructions. Last reviewed October 2026. General guidance only, not a diagnosis.